pem logo PennEngineering Inc.Leading the way in thin sheet fastening PEM ATLAS SI PEMSERTER STICKSCREW
Part Number Search:
Inventory Search     
>> Advanced Search

Ask a Technical Question

Commonly asked questions
Glossary of Terms
PEM & SI Products
Atlas Products
General Reference Tools & Charts
Metric Conversion Chart
Sheet Metal Gage
Galvanic Corrosion Chart
Fastener Installation Force
Plating Specifications
PEM® Brand Part Number Designation
• Surface Mount Cost Savings Calculator
• Product Notification
• Standard Drill Chart
Environmental / Govt. Compliance
ROHS
DFARS
IMDS Participation
NAS / MIL / NASM Cross Reference
NAS PEM® Brand Fasteners (self-clinching)
NAS Atlas Brand Fasteners (blind threaded inserts)
MIL/NASM Cross Reference PEM® brand Fasteners
MIL/NASM Cross Reference Atlas Brand Fasteners
Technical Articles
CAD Library
Part Prototype Sample Kits
Complete Part Number List
Technical Services
Fastener Installation Demo
PEM® Brand Fasteners (self-clinching)
Atlas Brand Fasteners (blind threaded inserts)
Trademarks
Identification Trademarks
Proper Use of a Trademark
Training
About Self-Clinching
About Blind Threaded Inserts
Request Training
Value-Added Options
Custom Hardware

MAThread® anti cross-threading feature
Blu-Coat™ thread mask
Self-Clinching Fastener Installation Do's And Dont's

"Do's"

Do provide mounting hole of specified size for each fastener.
Do install fastener into punch side of sheet.
Do make certain that shank (or pilot) is within hole before applying installation force.
Do apply squeezing force between parallel surfaces.
Do apply sufficient force to totally embed clinching ring around entire circumference and to bring shoulder squarely in contact with sheet. For some fasteners, installation will be complete when the head is flush with the panel surface.

"Don'ts"

Don't attempt to install a 300 series stainless steel fastener into a stainless steel sheet.
Don't install steel or stainless steel fasteners in aluminum panels before anodizing or finishing.
Don't deburr mounting holes on either side of sheet before installing fasteners - deburring will remove metal required for clinching fastener into sheet.
Don't install fastener closer to edge of sheet than minimum edge distance indicated by manufacturer - unless a special fixture is used to restrict bulging of sheet edge.
Don't over-squeeze. It will crush the head, distort threads, and buckle the sheet. Approximate installation forces are listed in performance data tables. Use this info as a guide. Be certain to determine optimum installation force by test prior to production runs.
Don't attempt to insert fastener with a hammer blow - under any circumstances. A hammer blow won't permit the sheet metal to flow and develop an interlock with the fastener's contour.
Don't install screw in the head side of fastener. Install from opposite side so that the fastener load is toward sheet. The clinching force is designed only to hold the fastener during handling and to resist torque during assembly.
Don't install fastener on pre-painted side of panel.


View PEM Brand Fastener Installation Demo.

 

 

 